Menu
Menu
Filter
Your Cart

Pyroelectric Laser Pulse Energy Sensors

The 919E-0.1-12-25K pyroelectric energy detector is for low energies and has a 10 mm diameter aperture. It can measure energies from 1 µJ to 10 mJ. It can operate at repetition rates up to 25 kHz and covers the spectral range from 0.15 - 12 µm. The sensor comes with a standard 1.5 meter ..
$0.00
Ex Tax:$0.00
The 919E-200U-8-25K pyroelectric energy detector is for very low energies and has an 8 mm diameter aperture. It can measure energies from..
$0.00
Ex Tax:$0.00
The 919E-10-24-10K general purpose pyroelectric energy detector offers a 24 mm diameter aperture. It can measure energies from 8µJ to 10J. It can operate at repetition rates up to 10 kHz and covers the spectral range from 0.15 - 3 µm. The sensor comes with a standard 1.5 meter cable for ..
$0.00
Ex Tax:$0.00
The 919E-0.1-12-250 high damage threshold pyroelectric energy detector is for low energies with a 12 mm aperture. It can measure energies from 7µJ up to 10mJ. It can operate at repetition rates up to 250 Hz and covers the spectral range from 0.15 - 3, and at 10.6µm. The sensor comes with..
$0.00
Ex Tax:$0.00
The 919E-10-35-10K pyroelectric energy detector comes with a diffuser for concentrated beams. It has a 35 mm diameter aperture and can measure energies from 20 µJ up to 10 J. It can operate at repetition rates up to 10 kHz and covers the spectral range from 0.19 - 2.2 and 2.94µm. The sen..
$0.00
Ex Tax:$0.00
The 919E-10-35-250 pyroelectric energy detector comes with a diffuser for concentrated beams. It has a 35 mm diameter aperture and can measure energies from 200 µJ up to 10 J. It can operate at repetition rates up to 250 Hz and covers the spectral range from 0.24 - 2.2 µm. The sensor com..
$0.00
Ex Tax:$0.00
The 919E-10-20-250 pyroelectric energy detector comes with a diffuser for concentrated beams. It has a 20 mm diameter aperture and can measure energies from 100 µJ to 10J. It can operate at repetition rates up to 250 Hz and covers the spectral range from 0.24 - 2.2 µm. The sensor comes w..
$0.00
Ex Tax:$0.00
The 919E-30-46-10K pyroelectric energy detector comes with a removable diffuser based attenuator for high energy YAG and erbium lasers. It has a 46 mm aperture with diffuser out and 33mm aperture with diffuser in. It can measure energies from 10 µJ up to 30 J. It can operate at repetition rate..
$0.00
Ex Tax:$0.00
The 919E-20U-10-20K photodiode energy detector is for low energies and has a 10 mm diameter aperture. It can measure energies from 1 nJ to 15µJ. It can operate at repetition rates up to 20 kHz and covers the spectral range from 0.19 - 1.1 µm. The sensor comes with a standard 1.5 meter ca..
$0.00
Ex Tax:$0.00
Showing 1 to 9 of 9 (1 Pages)
Filter Products