Menu
Menu
Filter
Your Cart

Scientific Research

The FRG-KT Frequency-Resolved Optical Gating (FROG) kit is based on the setup used in Newport Application Note 33 - Amplitude and Phase Characterization of Ultrashort Laser Pulses which describes the technique known as frequency-resolved optical gating (FROG). FROG is a technique that can be employ..
$0.00
Ex Tax:$0.00
The M-FRG-KT FROG kit is based on the setup used in Newport Application Note 33 - Amplitude and Phase Characterization of Ultrashort Laser Pulses which describes the technique known as frequency-resolved optical gating (FROG). FROG is a technique that can be employed in a variety of experimental ge..
$11,262.00
Ex Tax:$11,262.00
The 91150-KG3 Reference Cell and Meter is an integral part of solar simulator calibration and solar cell I-V characterization. It consists of a readout device and a 2 x 2 cm calibrated solar cell made of monocrystalline silicon with KG3 window. The cell is also equipped with a thermocouple assembled..
$2,908.00
Ex Tax:$2,908.00
The 91150-KG5 Reference Cell and Meter is an integral part of solar simulator calibration and solar cell I-V characterization. It consists of a readout device and a 2 x 2 cm calibrated solar cell made of monocrystalline silicon with KG5 window. The cell is also equipped with a thermocouple assembled..
$3,344.00
Ex Tax:$3,344.00
The 91150V Reference Cell and Meter is an integral part of solar simulator calibration and solar cell I-V characterization. It consists of a readout device and a 2 x 2 cm calibrated solar cell made of monocrystalline silicon and a fused silica window. The cell is also equipped with a thermocouple as..
$3,081.00
Ex Tax:$3,081.00
The SRCERT certification service prolongs the lifetime of any reference detector whose spectral responsivity is used for calibrated measurements. This can be applied to most of the flange-mount series detectors, as well as the references used in the QEPVSI-B and QuantX QE systems...
$0.00
Ex Tax:$0.00
The STPVCERT certification service prolongs the lifetime of the Oriel 91150V reference cell and meter. Newport recommends an annual certification for this device in order to ensure accuracy with sensitive measurements under an Oriel solar simulator...
$0.00
Ex Tax:$0.00
The GuideStar™ II Laser Beam Steering Correction System uses two Model 8784 GuideStar II Camera Sensors to provide continuous tracking of both laser beam positions and laser beam profiles. Designed for accuracy, reliability, and ease-of-use, the GuideStar II System is the answer to laser beam drift ..
$895.00
Ex Tax:$895.00
The SCG-800-CARS is a CARS (Coherent Anti-Stokes Raman Scattering) optimized supercontinuum generation fiber device for use with 800 nm femtosecond lasers. It contains 12 cm highly nonlinear photonic crystal fiber with zero dispersion points at ~775 and ~945 nm. The two closely spaced zero-dispersio..
$4,711.00
Ex Tax:$4,711.00
Provides temperature control for the device under test as well as vacuum positioning capability when used for IV measurements using any Oriel Sol3A, Sol2A, or Sol1A solar simulators and IV test station. The rail mounted design incorporates positions for up to a 6x6 sample and a calibrated solar ref..
$81.00
Ex Tax:$81.00
The PVIV-CHILLER is a circulating water bath heater and chiller, compatible with Oriel I-V test stations and Quantum Efficiency Measurement Systems. This chiller enables temperature control and stability of the sample under test when these test stations and measurement systems are used. It is mandat..
$4,496.00
Ex Tax:$4,496.00
The CARS-KT Coherent Anti-Stokes Raman Scattering Micro spectrometer solution is designed to be used with Ti:Sapphire femtosecond oscillators to perform CARS Microspectroscopy related experiments. In this solution, a Photonic Crystal Fiber is used to generate broadband Supercontinuum that can be use..
$0.00
Ex Tax:$0.00
Showing 1 to 12 of 80 (7 Pages)
Filter Products