Menu
Menu
Your Cart

Silicon Detector, 400-1100 nm, DB15 Calibration Module

Silicon Detector, 400-1100 nm, DB15 Calibration Module
Silicon Detector, 400-1100 nm, DB15 Calibration Module
Silicon Detector, 400-1100 nm, DB15 Calibration Module
Silicon Detector, 400-1100 nm, DB15 Calibration Module
Silicon Detector, 400-1100 nm, DB15 Calibration Module
Silicon Detector, 400-1100 nm, DB15 Calibration Module
Silicon Detector, 400-1100 nm, DB15 Calibration Module
Silicon Detector, 400-1100 nm, DB15 Calibration Module
Silicon Detector, 400-1100 nm, DB15 Calibration Module
  • Brand:
  • Product Code: 818-SL/DB
$534.00
Ex Tax: $534.00

Available Options

The 818-SL/DB Silicon (Si) Photodetector is supplied with a NIST traced calibration report that details individual detector responsivity measured with and without attenuator. Exclusive OD3 attenuator technology extends the calibrated optical dynamic range of our photodiode sensor heads by three decades. The serial numbers for the detector and the attenuator are matched to ensure NIST traceability. The 10 mm clear aperture with the cross hair will improve the detector alignment to the input optical beam more accurately and help avoid detector overfilling. This model includes a BNC/DB15 calibration module. The adapter contains the detector calibration data, model number, serial number and calibration date for seamless operation. Also available are a variety of accessories such as collimating lens assemblies, fiber optic adapters, and a bare fiber adapter, and a 1 inch optic holder. Note that Model 818-SL/CM is available offline only. Model 818-SL is no longer available.

Please refer to Newport Power Meter and Detector Legacy and Compatibility for a complete list of meters that are compatible with this model.

feature
Attenuator OD3, Detachable
Cable Length 1.5 m
Calibration Uncertainty With Attenuator ±1% @ 400-940nm, ±4% @ 941-1100nm
Calibration Uncertainty without Attenuator ±1% @ 400-940nm, ±4% @ 941-1100 nm
Clear Aperture 10.3 mm
Connector Type DB15
Detector Type Standard
Linearity ±0.5 %
Material Silicon
Maximum Measurable Power 2.0 W
Maximum Measurable Power Without Attenuator 4 mW with 1830-R and 1936-R, 2.5 mW with 843-R, 1919-R, and 841-PE-USB
Maximum Power Density 30 W/cm2
Maximum Power Density without Attenuator 3 W/cm2
Maximum Pulse Energy with Attenuator 5 µJ
Maximum Pulse Energy Without Attenuator 5 nJ
Minimum Detectable Power 20 pW (1936-R/2936-R), 100 pW (1830-R, 843-R, 1919-R, 841-PE-USB), 5 nW (1918-R)
Rise Time ≤2 µs
RoHS Compliant
Sensor Size Ø11.3 mm
Spectral Range 400 - 1100 nm
Uniformity ±2 %

Write a review