The TS-510 is a calibrated NTC 10 kΩ leaded thermistor with a baked on phenolic coating for durability and long-term stability. These have solid nickel 30 AWG wires with Teflon insulation to provide insulation when assembled in a heat sink or plate with a lead length of 3 inches (76 mm). They are id..
The 91150-KG3 Reference Cell and Meter is an integral part of solar simulator calibration and solar cell I-V characterization. It consists of a readout device and a 2 x 2 cm calibrated solar cell made of monocrystalline silicon with KG3 window. The cell is also equipped with a thermocouple assembled..
The 91150-KG5 Reference Cell and Meter is an integral part of solar simulator calibration and solar cell I-V characterization. It consists of a readout device and a 2 x 2 cm calibrated solar cell made of monocrystalline silicon with KG5 window. The cell is also equipped with a thermocouple assembled..
The 91150V Reference Cell and Meter is an integral part of solar simulator calibration and solar cell I-V characterization. It consists of a readout device and a 2 x 2 cm calibrated solar cell made of monocrystalline silicon and a fused silica window. The cell is also equipped with a thermocouple as..
The 71617 Amplified Germanium Photodetector has a built-in trans impedance amplifier. This uncalibrated 5 mm diameter Germanium detector has a broad spectral range from 700 to 1800 nm. The amplifier enables selectable gain levels from 104 V/A to 109 V/A. It also offers three selectable time constant..
The 71653 Calibrated Germanium Photodetector is operated in photovoltaic mode for best DC and low frequency performance. This 5 mm diameter Germanium detector has a broad spectral range from 700 to1800 nm, which enables spectroradiometric measurements to be made. This detector has been integrated i..
The 71889 Amplified, UV-Enhanced Silicon Photodetector is operated in photovoltaic mode for best DC and low frequency performance. This calibrated 10 mm x 10 mm Silicon detector has a 200 to 1100 nm spectral range, which enables spectroradiometric measurements. This version has a built-in trans imp..
The 71650 Calibrated, UV-Enhanced Silicon Photodetector is operated in photovoltaic mode for best DC and low frequency performance. This 10 mm x 10 mm Silicon detector has a 200 to 1100 nm calibration range, which enables spectroradiometric measurements to be made. This detector has been integrated ..
The 818-IR/DB Germanium (Ge) Photodetector is supplied with a NIST traced calibration report that details individual detector responsivity measured with and without attenuator. Exclusive OD3 attenuator technology extends the calibrated optical dynamic range of our photodiode sensor heads by three de..
The new RoHS compliant 918D Series Germanium Photodetector for low optical power measurements. Features include integrated calibration-data storage, built-in OD1 attenuation filter with automatic On/Off detection, and temperature sensing electronics for temperature drift compensation. Germanium (Ge..
The new RoHS compliant 918D Series Germanium Photodetector for low optical power measurements. Features include integrated calibration-data storage, built-in OD2 attenuation filter with automatic On/Off detection, and temperature sensing electronics for temperature drift compensation. Germanium (Ge..
The new RoHS compliant 918D Series Germanium Photodetector for low optical power measurements. Features include integrated calibration-data storage, built-in OD3 attenuation filter with automatic On/Off detection, and temperature sensing electronics for temperature drift compensation. Germanium (Ge..