PXI-8422/4
The National Instruments PXI-8422/4 is a four-port isolated RS-232 interface for PXI systems.
Request current pricing and lead time for this model. Our team will confirm the exact equipment configuration and condition.

The National Instruments PXI-8422/4 is a four-port isolated RS-232 interface for PXI systems.
Request current pricing and lead time for this model. Our team will confirm the exact equipment configuration and condition.
Key product information and technical features.
This module adds four isolated serial ports to a PXI system. NI identifies part number 777736-04 as the PXI-8422/4.
Its modular port connectors require conversion cables for DB-9 or DB-25 connections. Check the legacy software environment before integration: NI-Serial 17.0 removed support for the PXI-8422 family.
Verified product specifications.
| Serial ports | 4 ports |
|---|---|
| Maximum baud rate | 115.2 kbps |
| I/O connector | 10-position modular jack (10P10C) |
| Dimensions | 100 × 160 mm |
| Supply voltage | +5 VDC |
| Supply current | 500 typical; 750 maximum mA |
| Continuous isolation, port-to-port and port-to-host | 60 VDC, CAT I |
| Isolation withstand, port-to-port and port-to-host | 2000 Vrms, verified by a 5-second dielectric withstand test |
Confirm condition, included accessories and revision before ordering.
Confirmed per unit.
Device / accessories confirmed in quote.
Exact revision confirmed when relevant.
Review system components and compatibility requirements.
Manufacturer
Hardware platform
Isolated RS-232 interface
Conversion cables required for DB-9 or DB-25 connections.
Manuals, software and technical resources for this model.
Review shipping, warranty and return terms before ordering.
Choose pricing, rental or repair for this exact model.
Product-specific answers based on available technical information.
It is the four-port isolated RS-232 model. The PXI-8422/2 is the separate two-port variant.
No. The four-port board uses 10-position modular jacks and requires conversion cables for DB-9 or DB-25 connections.
No. It is a 2000 Vrms, five-second dielectric withstand rating. Continuous isolation is 60 VDC, CAT I.
No. NI explicitly removed PXI-8422 support in NI-Serial 17.0. Verify an earlier driver and operating-system combination before use.