NI SCC-SG03 2-channel half-bridge strain-gage input module - equipment photo 1
NI SCC-SG03 2-channel half-bridge strain-gage input module - equipment photo 1 additional viewNI SCC-SG03 2-channel half-bridge strain-gage input module - equipment photo 1 additional viewNI SCC-SG03 2-channel half-bridge strain-gage input module - equipment photo 1 additional viewNI SCC-SG03 2-channel half-bridge strain-gage input module - equipment photo 1 additional view
5 images: additional views below.Click to enlarge
National Instruments · SCC signal conditioning system

NI SCC-SG03

NI SCC-SG03 is an SCC Series 2-channel half-bridge strain-gage input module designed for use in NI SCC carrier-based measurement systems.

ManufacturerNational Instruments
ModelSCC-SG03
Product Type2-channel half-bridge strain-gage input module
● Available to Order
Condition: confirmed per unit

Request current pricing and lead time for this model. Our team will confirm the exact equipment configuration and condition.

Fast RFQ

Quote: SCC-SG03

We will reply by email.
Free Shippingfull policy linked
30-Day Warrantystandard coverage
30-Day Returnspolicy applies
Technical Supportmodel & compatibility help
Channels2 differential strain-gage channels
Input range±100 mV
Gain100
Bandwidth1.6 kHz
Input noise1 µVrms
Gain error±0.8 % of reading max
SOHO Assistant
Ask about this exact model, a replacement, accessory, driver, rental or repair question.
Ask about specifications, compatibility, availability, rental or repair.
Ask SOHO Assistant
Overview

Product overview

Key product information and technical features.

NI SCC-SG03 is an SCC Series strain-gage input module for half-bridge measurements in the NI SCC platform. NI distinguishes this model from other SCC-SG variants: SCC-SG01 is quarter-bridge 120 Ω, SCC-SG02 is quarter-bridge 350 Ω, SCC-SG03 is half-bridge, SCC-SG04 is full-bridge, and SCC-SG24 is full-bridge for at least 350 Ω. The official NI configuration worksheet and EOL listing identify SCC-SG03 with part number 777459-15 as a 2-channel half-bridge module.

The module provides two differential strain-gage channels with a ±100 mV input range and fixed gain of 100 on each channel. NI specifies 1.6 kHz bandwidth with a single-pole RC filter, 1 µVrms input noise, gain error of ±0.8% of reading maximum, and post-calibration offset error of ±5 µV. Additional published performance values include 110 dB minimum CMRR, ±2.5 mV RTI offset-nulling adjustment range, and a maximum output range of ±10 VDC.

For bridge excitation and completion, NI specifies one excitation source at +2.5 VDC ±0.4% with 42 mA current drive. The SCC-SG03 half-bridge completion network uses two 10 kΩ resistors with ±0.02% ratio tolerance and ±2 ppm/°C tracking TCR, and NI lists the half-bridge completion reference accuracy as 1.25 VDC ±0.4%. The user guide documents Half-Bridge Type I and Half-Bridge Type II wiring, and also notes a quarter-bridge type II arrangement that uses SCC-SG03 half-bridge completion.

  • Supports half-bridge strain-gage configurations.
  • Provides 2 differential strain-gage channels.
  • Supports Half-Bridge Type I and Half-Bridge Type II wiring; NI also notes a quarter-bridge type II arrangement using SCC-SG03 half-bridge completion.
  • Includes +2.5 VDC excitation with 42 mA current drive.
  • Provides ±28 VDC overvoltage protection powered on and powered off for SCC-SG0X modules.
Verified specifications

Technical data

Verified product specifications.

Channels2 differential strain-gage channels
Input range±100 mV
Gain100
Bandwidth1.6 kHz
Input noise1 µVrms
Gain error±0.8 % of reading max
Offset error±5 µV (post calibration)
Offset-nulling adjustment range±2.5 mV (RTI)
CMRR110 dB min
Output range±10 VDC max
Excitation voltage+2.5 ±0.4 VDC
Excitation current drive42 mA
Half-bridge completion resistorstwo 10 kΩ resistors
Completion network ratio tolerance±0.02 %
Tracking TCR±2 ppm/°C
Half-bridge completion reference accuracy1.25 ±0.4 VDC
Input impedance, powered on10 MΩ
Input impedance, powered off or overload10 kΩ
Overvoltage protection±28 VDC
Recommended warm-up time5 min
Maximum working voltage, channel-to-earth±12 VDC, Installation Category I
Maximum working voltage, module-to-module±12 VDC, Installation Category I
Condition & included items

What the actual unit includes

Confirm condition, included accessories and revision before ordering.

Condition

Confirmed per unit.

Included

Device / accessories confirmed in quote.

Revision

Exact revision confirmed when relevant.

Compatibility

Complete the measurement chain

Review system components and compatibility requirements.

National Instruments

Manufacturer

SCC signal conditioning system

Platform

SCC-SG03

2-channel half-bridge strain-gage input module

Interface

SC-2345/SC-2350 SCC carrier module interface

Manuals & software

Technical resources

Manuals, software and technical resources for this model.

Shipping, warranty & returns

Commercial terms

Review shipping, warranty and return terms before ordering.

Shipping
Free Shipping. Full policy terms apply.
Warranty
30-Day Warranty. Standard coverage applies.
Returns
30-Day Returns. Return policy applies.
Price / Availability
Contact SOHO ProLab for current quote and availability.
Lifecycle services

Source, rent or repair the exact model

Choose pricing, rental or repair for this exact model.

Explore equipment

Data Acquisition and Control Systems

Shipping, warranty and returns

FAQ

Product-specific questions

Product-specific answers based on available technical information.

What is the NI SCC-SG03?

NI identifies the SCC-SG03 as an SCC Series strain-gage input module for half-bridge configurations. The official configuration worksheet and EOL table identify it as part number 777459-15 and describe it as a 2-channel half-bridge module.

How is SCC-SG03 different from other SCC-SG modules?

NI differentiates the family by bridge type: SCC-SG01 is quarter-bridge 120 Ω, SCC-SG02 is quarter-bridge 350 Ω, SCC-SG03 is half-bridge, SCC-SG04 is full-bridge, and SCC-SG24 is full-bridge for at least 350 Ω. SCC-SG11 is a separate shunt calibration module, not an SCC-SG03 variant.

What carrier system does SCC-SG03 use?

NI documents the SCC-SG03 for use in SC-2345/2350 SCC carrier systems and references SCC power module arrangements such as SCC-PWR01, SCC-PWR02, and SCC-PWR03.

What are the main electrical measurement specifications of SCC-SG03?

According to NI, the SCC-SG03 provides 2 differential channels, ±100 mV input range, fixed gain of 100, 1.6 kHz bandwidth, and ±10 VDC maximum output range.