National Instruments RM-26999 product image 1
National Instruments RM-26999 product image 1 additional viewNational Instruments RM-26999 product image 1 additional viewNational Instruments RM-26999 product image 1 additional viewNational Instruments RM-26999 product image 1 additional viewNational Instruments RM-26999 product image 1 additional view
6 images: additional views below.Click to enlarge
National Instruments · PXI Platform

NI RM-26999

NI RM-26999 is an NI high power rackmount terminal block designed as a rack-mounted signal conditioning device for power measurements, with official NI documentation identifying orderable part number 786328-01.

ManufacturerNational Instruments
ModelRM-26999
Product TypeHigh Power Rackmount Terminal Block / rack-mounted signal conditioning device for power measurements
● Available to Order
Condition: confirmed per unit

Request current pricing and lead time for this model. Our team will confirm the exact equipment configuration and condition.

Fast RFQ

Quote: RM-26999

We will reply by email.
Free Shippingfull policy linked
30-Day Warrantystandard coverage
30-Day Returnspolicy applies
Technical Supportmodel & compatibility help
Orderable part number786328-01
Voltage input channels4
Current transducer ports4
Maximum voltage rating1000 V, Category II
Maximum voltage rating2000 V peak, other non-MAINs circuits
DAQ-side current input ranges±1, ±2, ±5, ±10 V
SOHO Assistant
Ask about this exact model, a replacement, accessory, driver, rental or repair question.
Ask about specifications, compatibility, availability, rental or repair.
Ask SOHO Assistant
Overview

Product overview

Key product information and technical features.

NI RM-26999 is a high power rackmount terminal block that NI also describes as a rack-mounted signal conditioning device for power measurements. Official NI sources identify RM-26999 as a primary hardware module rather than a cable or accessory, and the reviewed NI product page shows a single orderable part number, 786328-01. NI positions the unit for connection to simultaneous-sampling multifunction I/O devices for power measurement setups.

The RM-26999 provides 4 voltage input channels and 4 current transducer ports. NI states that the unit does not directly measure current; instead, it works with current transducers and supports transducer connections that include ±10 V signal lines, +15 V and -15 V transducer supply outputs, and calibration/status lines. On the DAQ side, NI specifies supported current input ranges of ±1 V, ±2 V, ±5 V, and ±10 V.

For measurement performance, NI specifies 200:1 attenuation, typical DC common-mode rejection greater than 100 dB, single-ended-to-earth input impedance of 10 MΩ || 4.7 pF, and 1 MHz bandwidth at -3 dB. Additional published specifications include burden resistor selections of 0.5 Ω, 1 Ω, 2 Ω, 5 Ω, and 10 Ω, plus shunt accuracy of ±0.05% using a metal foil shunt rated to 2 W maximum. Maximum voltage ratings are 1,000 V Category II and 2,000 V peak for other non-MAINs circuits.

  • High power rackmount terminal block; NI also describes it as a rack-mounted signal conditioning device for power measurements.
  • Provides 4 voltage input channels.
  • Provides 4 current transducer ports and does not directly measure current.
  • Current transducer port supports ±10 V signal plus +15 V / -15 V transducer supply outputs and calibration/status lines.
  • Designed to connect to simultaneous-sampling multifunction I/O devices for power measurements.
Verified specifications

Technical data

Verified product specifications.

Orderable part number786328-01
Voltage input channels4
Current transducer ports4
Maximum voltage rating1000 V, Category II
Maximum voltage rating2000 V peak, other non-MAINs circuits
DAQ-side current input ranges±1, ±2, ±5, ±10 V
Burden resistors0.5, 1, 2, 5, 10 Ω
Shunt accuracy±0.05%
Shunt type and ratingmetal foil, 2 W max
Attenuation200:1
CMRR>100 dB DC, typical
Input impedance, single-ended to earth10 MΩ || 4.7 pF
Bandwidth (-3 dB)1 MHz
Noise contribution13 mV RMS, RTI, 5 MHz bandwidth
Calibration interval2 years
Power input24 V DC ±5%
Maximum power consumption150 W
Recommended power suppliesNI PS-15 (5 A, 120 W) or NI PS-16 (10 A, 240 W)
Dimensions482.6 × 43.9 × 156.2 mm
Dimensions19.00 × 1.73 × 6.15 in
Weight3020 g
Condition & included items

What the actual unit includes

Confirm condition, included accessories and revision before ordering.

Condition

Confirmed per unit.

Included

Device / accessories confirmed in quote.

Revision

Exact revision confirmed when relevant.

Compatibility

Complete the measurement chain

Review system components and compatibility requirements.

National Instruments

Manufacturer

PXI Platform

Platform

RM-26999

High Power Rackmount Terminal Block / rack-mounted signal conditioning device for power measurements

Interface

Rack-mounted voltage and current-transducer signal conditioning interface for simultaneous-sampling multifunction I/O devices

Manuals & software

Technical resources

Manuals, software and technical resources for this model.

Shipping, warranty & returns

Commercial terms

Review shipping, warranty and return terms before ordering.

Shipping
Free Shipping. Full policy terms apply.
Warranty
30-Day Warranty. Standard coverage applies.
Returns
30-Day Returns. Return policy applies.
Price / Availability
Contact SOHO ProLab for current quote and availability.
Lifecycle services

Source, rent or repair the exact model

Choose pricing, rental or repair for this exact model.

Explore equipment

Test Equipment Parts & Accessories

Shipping, warranty and returns

FAQ

Product-specific questions

Product-specific answers based on available technical information.

Is the NI RM-26999 a primary hardware module or just an accessory?

Official NI documentation identifies RM-26999 as the primary hardware module and describes it as a high power rackmount terminal block and rack-mounted signal conditioning device for power measurements. NI separately lists cables, shunts, and certain PXIe modules as accessories or compatible items.

Does the NI RM-26999 directly measure current?

No. NI states that the RM-26999 does not directly measure current and instead uses current transducers connected through its 4 current transducer ports.

What power input does the NI RM-26999 require?

NI specifies a 24 V DC ±5% power input, with maximum power consumption of 150 W. NI also recommends the PS-15 or PS-16 power supplies.