National Instruments PXIe-5605 product image 1
National Instruments PXIe-5605 product image 1 additional viewNational Instruments PXIe-5605 product image 1 additional viewNational Instruments PXIe-5605 product image 1 additional viewNational Instruments PXIe-5605 product image 1 additional view
5 images: additional views below.Click to enlarge
National Instruments · PXI Express

NI PXIe-5605

NI PXIE-5605 is an NI PXI Express RF downconverter module documented by NI as a constituent module in the PXIe-5665 14 GHz vector signal analyzer system and listed as supported hardware for the NI-RFSA driver.

ManufacturerNational Instruments
ModelPXIe-5605
Product TypeRF downconverter module
● Available to Order
Condition: confirmed per unit

Request current pricing and lead time for this model. Our team will confirm the exact equipment configuration and condition.

Fast RFQ

Quote: PXIE-5605

We will reply by email.
Free Shippingfull policy linked
30-Day Warrantystandard coverage
30-Day Returnspolicy applies
Technical Supportmodel & compatibility help
ManufacturerNI
ModelPXIe-5605
Product typeRF downconverter
PlatformPXI Express
Documented board assembly part number199749A-01L or later
SOHO Assistant
Ask about this exact model, a replacement, accessory, driver, rental or repair question.
Ask about specifications, compatibility, availability, rental or repair.
Ask SOHO Assistant
Overview

Product overview

Key product information and technical features.

NI PXIE-5605 is identified in official NI documentation as the NI PXIe-5605 RF downconverter. NI distinguishes this module from complete vector signal analyzer products: the PXIe-5665 system comprises the PXIe-5605 RF downconverter, a PXIe-5653 LO module, and a PXIe-5622 IF digitizer. In NI-RFSA supported-hardware tables, PXIe-5605 appears under RF Signal Downconverter rather than under Vector Signal Analyzer products.

Within the documented PXIe-5665 MIMO platform configuration, the PXIe-5605 serves as the center module between its required companion instruments. NI’s installation guidance states that the PXIe-5622 IF digitizer installs immediately to the left of the PXIe-5605 RF downconverter, while the PXIe-5653 LO module installs immediately to the right. This confirms the module’s role in a multi-instrument RF analysis chain rather than as a standalone analyzer SKU.

Official NI sources also confirm support and service-related details for the module itself. The NI-RFSA driver supported-hardware documentation includes the PXIe-5605, and the supported-hardware table does not list NI-RFSA Soft Front Panel analyzer support for this module in the way complete VSA products such as PXIe-5665 are listed. NI’s Letter of Volatility for the PXIe-5605 further documents flash-stored product identification, calibration constants, and calibration metadata, and references NI RFSA external calibration workflow functions for clearing user-defined calibration metadata.

  • Identified by NI as the PXIe-5605 RF downconverter module.
  • Listed in NI-RFSA supported hardware under RF Signal Downconverter, separate from complete Vector Signal Analyzer products.
  • Supported by the NI-RFSA driver.
  • Stores product identification, calibration constants, and calibration metadata in flash memory.
  • Supports user-facing external calibration workflow through NI RFSA calibration functions referenced in NI documentation.
Verified specifications

Technical data

Verified product specifications.

ManufacturerNI
ModelPXIe-5605
Product typeRF downconverter
PlatformPXI Express
Documented board assembly part number199749A-01L or later
Condition & included items

What the actual unit includes

Confirm condition, included accessories and revision before ordering.

Condition

Confirmed per unit.

Included

Device / accessories confirmed in quote.

Revision

Exact revision confirmed when relevant.

Compatibility

Complete the measurement chain

Review system components and compatibility requirements.

National Instruments

Manufacturer

PXI Express

Platform

PXIE-5605

RF downconverter module

Interface

PXI Express

Manuals & software

Technical resources

Manuals, software and technical resources for this model.

Shipping, warranty & returns

Commercial terms

Review shipping, warranty and return terms before ordering.

Shipping
Free Shipping. Full policy terms apply.
Warranty
30-Day Warranty. Standard coverage applies.
Returns
30-Day Returns. Return policy applies.
Price / Availability
Contact SOHO ProLab for current quote and availability.
Lifecycle services

Source, rent or repair the exact model

Choose pricing, rental or repair for this exact model.

Explore equipment

PXI Platform

Shipping, warranty and returns

FAQ

Product-specific questions

Product-specific answers based on available technical information.

Is the PXIe-5605 a complete vector signal analyzer?

No. NI documentation identifies the PXIe-5605 as an RF downconverter module. The PXIe-5665 vector signal analyzer system comprises the PXIe-5605 RF downconverter, PXIe-5653 LO module, and PXIe-5622 IF digitizer.

Which NI driver supports the PXIe-5605?

The PXIe-5605 is listed as supported hardware for the NI-RFSA driver in NI’s supported-hardware documentation.

What companion modules are documented with the PXIe-5605 in NI’s PXIe-5665 system?

NI documents the PXIe-5605 for use with the PXIe-5653 LO module and the PXIe-5622 IF digitizer in the PXIe-5665 system.

What module-specific data does NI say is stored on the PXIe-5605?

NI’s Letter of Volatility states that flash memory stores product identification, calibration constants, and calibration metadata for the PXIe-5605.

Ask SOHO AssistantProduct & compatibility help