National Instruments PXIe-5601 product image 1
National Instruments PXIe-5601 product image 1 additional viewNational Instruments PXIe-5601 product image 1 additional viewNational Instruments PXIe-5601 product image 1 additional viewNational Instruments PXIe-5601 product image 1 additional view
5 images: additional views below.Click to enlarge
National Instruments · PXI Express

NI PXIe-5601

NI PXIE-5601 is a PXI Express RF signal downconverter module designed for RF signal path applications where a dedicated downconverter is used with companion NI modules rather than as a standalone analyzer.

ManufacturerNational Instruments
ModelPXIe-5601
Product TypeRF signal downconverter module
● Available to Order
Condition: confirmed per unit

Request current pricing and lead time for this model. Our team will confirm the exact equipment configuration and condition.

Fast RFQ

Quote: PXIE-5601

We will reply by email.
Free Shippingfull policy linked
30-Day Warrantystandard coverage
30-Day Returnspolicy applies
Technical Supportmodel & compatibility help
Frequency range10 MHz to 6.6 GHz
RF input attenuation0 to 50 dB
RF input attenuation step size1 dB
RF input connectorSMA female, 50 Ω nominal, AC coupled
Maximum safe continuous RF power at RF IN with attenuation enabled+30 dBm
Maximum safe continuous RF power at RF IN with attenuation disabled+20 dBm
SOHO Assistant
Ask about this exact model, a replacement, accessory, driver, rental or repair question.
Ask about specifications, compatibility, availability, rental or repair.
Ask SOHO Assistant
Overview

Product overview

Key product information and technical features.

NI PXIE-5601 is an RF signal downconverter module for the PXI Express platform. NI documentation identifies it specifically as an RF Signal Downconverter, and in PXIe-5663 system documentation it is referred to as the NI 5601 RF downconverter module rather than a complete standalone analyzer. This distinction is important for catalog accuracy because the PXIe-5601 is the downconversion stage within a modular RF measurement system, not the full analyzer by itself.

The module provides a 10 MHz to 6.6 GHz frequency range and uses SMA female, 50 Ω, AC-coupled connections for RF IN and IF OUT. NI specifies nominal RF input attenuation from 0 dB to 50 dB in 1 dB steps. Maximum safe continuous RF power at RF IN is +30 dBm with RF attenuation enabled at 8 dB or greater, or +20 dBm with attenuation disabled at 0 dB. IF center frequency options are 53 MHz, 187.5 MHz, or Bypass, with the bypass path noted for 10 MHz to 300 MHz.

For local oscillator routing, the PXIe-5601 includes LO IN and LO OUT connectors, both SMA female, 50 Ω, and AC coupled. NI lists nominal LO frequency from 173 MHz to 6.4125 GHz and nominal LO amplitude of 0 dBm. In the PXIe-5663 documentation, NI states that IF OUT connects to the IF IN on the NI 5622 IF digitizer and LO IN connects to the RF OUT on the NI 5652 LO source, illustrating the module’s role in a multi-module RF system.

  • Identified by NI as an RF Signal Downconverter.
  • Referenced by NI as the NI 5601 RF downconverter module in PXIe-5663 system documentation.
  • Provides nominal RF input attenuation from 0 dB to 50 dB in 1 dB steps.
  • Supports IF center frequency selections of 53 MHz, 187.5 MHz, or Bypass.
  • Uses SMA female, 50 Ω, AC-coupled RF, IF, and LO connections.
Verified specifications

Technical data

Verified product specifications.

Frequency range10 MHz to 6.6 GHz
RF input attenuation0 to 50 dB
RF input attenuation step size1 dB
RF input connectorSMA female, 50 Ω nominal, AC coupled
Maximum safe continuous RF power at RF IN with attenuation enabled+30 dBm
Maximum safe continuous RF power at RF IN with attenuation disabled+20 dBm
IF OUT connectorSMA female, 50 Ω nominal, AC coupled
IF center frequency53 MHz; 187.5 MHz; Bypass
Bypass path frequency10 MHz to 300 MHz
LO IN / LO OUT connectorsSMA female, 50 Ω nominal, AC coupled
LO frequency173 MHz to 6.4125 GHz nominal
LO amplitude0 dBm nominal
Module form factor3U, one-slot PXI Express module
Dimensions21.6 × 2.0 × 13.0 cm
Weight454 g
Calibration interval1 year
Condition & included items

What the actual unit includes

Confirm condition, included accessories and revision before ordering.

Condition

Confirmed per unit.

Included

Device / accessories confirmed in quote.

Revision

Exact revision confirmed when relevant.

Compatibility

Complete the measurement chain

Review system components and compatibility requirements.

National Instruments

Manufacturer

PXI Express

Platform

PXIE-5601

RF signal downconverter module

Interface

PXI Express

Manuals & software

Technical resources

Manuals, software and technical resources for this model.

Shipping, warranty & returns

Commercial terms

Review shipping, warranty and return terms before ordering.

Shipping
Free Shipping. Full policy terms apply.
Warranty
30-Day Warranty. Standard coverage applies.
Returns
30-Day Returns. Return policy applies.
Price / Availability
Contact SOHO ProLab for current quote and availability.
Lifecycle services

Source, rent or repair the exact model

Choose pricing, rental or repair for this exact model.

Explore equipment

PXI Platform

Shipping, warranty and returns

FAQ

Product-specific questions

Product-specific answers based on available technical information.

Is the NI PXIE-5601 a standalone signal analyzer?

No. NI identifies the PXIe-5601 as an RF signal downconverter module, and NI PXIe-5663 documentation shows it used with companion modules such as the NI 5622 IF digitizer and NI 5652 LO source.

What frequency range does the PXIe-5601 cover?

NI specifies a frequency range of 10 MHz to 6.6 GHz.

What are the RF input connection and attenuation characteristics of the PXIe-5601?

NI specifies an SMA female, 50 Ω nominal, AC-coupled RF input with nominal attenuation from 0 dB to 50 dB in 1 dB steps.

What calibration interval does NI specify for the PXIe-5601?

NI specifies a calibration interval of 1 year.

Ask SOHO AssistantProduct & compatibility help