NI PXI-1409 Monochrome image acquisition device / frame grabber module - equipment photo 1
NI PXI-1409 Monochrome image acquisition device / frame grabber module - equipment photo 1 additional viewNI PXI-1409 Monochrome image acquisition device / frame grabber module - equipment photo 1 additional viewNI PXI-1409 Monochrome image acquisition device / frame grabber module - equipment photo 1 additional viewNI PXI-1409 Monochrome image acquisition device / frame grabber module - equipment photo 1 additional viewNI PXI-1409 Monochrome image acquisition device / frame grabber module - equipment photo 1 additional view
6 images: additional views below.Click to enlarge
National Instruments · PXI

NI PXI-1409

NI PXI-1409 is a PXI monochrome image acquisition device in the IMAQ 1409 family, designed for frame grabbing from monochrome video sources in PXI-based machine vision and imaging systems.

ManufacturerNational Instruments
ModelPXI-1409
Product TypeMonochrome image acquisition device / frame grabber module
● Available to Order
Condition: confirmed per unit

Request current pricing and lead time for this model. Our team will confirm the exact equipment configuration and condition.

Fast RFQ

Quote: PXI-1409

We will reply by email.
Free Shippingfull policy linked
30-Day Warrantystandard coverage
30-Day Returnspolicy applies
Technical Supportmodel & compatibility help
Bus / form factorPXI
Video inputs4 monochrome inputs
Supported video standardsRS-170/NTSC; CCIR/PAL; VGA 640 × 480 at 60 Hz; programmable variable scan
ADC resolution10 bit
Gray levels1024 levels
Sampling rate2 to 40 MHz externally clocked
SOHO Assistant
Ask about this exact model, a replacement, accessory, driver, rental or repair question.
Ask about specifications, compatibility, availability, rental or repair.
Ask SOHO Assistant
Overview

Product overview

Key product information and technical features.

NI PXI-1409 is a monochrome image acquisition device for PXI systems in the IMAQ PXI/PCI-1409 family. NI describes the 1409 family as high-quality, high-accuracy monochrome image acquisition devices, with the PXI-1409 specifically representing the PXI bus variant rather than the PCI version. This distinction matters when matching the module to the host platform, because the same family documentation also covers the separate PCI-1409 model. Source: https://download.ni.com/support/manuals/322811b.pdf ; https://docs-be.ni.com/bundle/372152a/raw/resource/enus/372152a.pdf

The module supports several monochrome video acquisition modes, including RS-170/NTSC, CCIR/PAL, VGA 640 × 480 at 60 Hz, and programmable variable scan. NI specifies four monochrome video inputs, a 10-bit ADC providing 1024 gray levels, and sampling from 2 MHz to 40 MHz when externally clocked. The internal pixel clock range is 11 MHz to 40 MHz, and typical frequency response is rated at 30 MHz at -3 dB. Source: https://download.ni.com/support/manuals/322811b.pdf

For signal connection and control, the PXI-1409 provides a front-panel BNC connection for VIDEO0 and a 68-pin VHDCI connector for video, sync, trigger, and control signals. NI also documents four general-purpose control lines, four external I/O lines, and four video sources. Acquired images can be stored in onboard frame memory or transferred directly to system memory, supporting different acquisition and processing architectures. Source: https://download.ni.com/support/manuals/322811b.pdf

  • PXI monochrome image acquisition device / frame grabber module in the IMAQ 1409 family.
  • Supports RS-170/NTSC, CCIR/PAL, VGA 640 × 480 at 60 Hz, and programmable variable scan video formats.
  • Provides 4 monochrome video inputs.
  • Uses a 10-bit ADC with 1024 gray levels.
  • Images can be stored in onboard frame memory or transferred directly to system memory.
  • Front-panel connectivity includes VIDEO0 on BNC and a 68-pin VHDCI for video, sync, trigger, and control connections.
Verified specifications

Technical data

Verified product specifications.

Bus / form factorPXI
Video inputs4 monochrome inputs
Supported video standardsRS-170/NTSC; CCIR/PAL; VGA 640 × 480 at 60 Hz; programmable variable scan
ADC resolution10 bit
Gray levels1024 levels
Sampling rate2 to 40 MHz externally clocked
Internal pixel clock range11 to 40 MHz
Frequency response30 MHz (-3 dB typ)
Input impedance75 ±1% Ω
Analog input range700 mV calibrated black-to-white; 50 mV to 1.40 V full scale
General-purpose control lines4 lines
External I/O lines4 lines
Video sources4 sources
Front connectorBNC for VIDEO0; 68-pin VHDCI for video/sync/trigger/control
Module dimensions10 × 16 cm
Weight0.172 kg
Operating temperature0 to 55 °C
Condition & included items

What the actual unit includes

Confirm condition, included accessories and revision before ordering.

Condition

Confirmed per unit.

Included

Device / accessories confirmed in quote.

Revision

Exact revision confirmed when relevant.

Compatibility

Complete the measurement chain

Review system components and compatibility requirements.

National Instruments

Manufacturer

PXI

Platform

PXI-1409

Monochrome image acquisition device / frame grabber module

Interface

PXI

Manuals & software

Technical resources

Manuals, software and technical resources for this model.

Shipping, warranty & returns

Commercial terms

Review shipping, warranty and return terms before ordering.

Shipping
Free Shipping. Full policy terms apply.
Warranty
30-Day Warranty. Standard coverage applies.
Returns
30-Day Returns. Return policy applies.
Price / Availability
Contact SOHO ProLab for current quote and availability.
Lifecycle services

Source, rent or repair the exact model

Choose pricing, rental or repair for this exact model.

Explore equipment

PXI Platform

Shipping, warranty and returns

FAQ

Product-specific questions

Product-specific answers based on available technical information.

What is the NI PXI-1409?

According to NI, the PXI-1409 is a high-quality monochrome image acquisition device for PXI systems in the IMAQ 1409 family.

Is PXI-1409 the same as PCI-1409?

No. NI documents PXI-1409 and PCI-1409 as separate bus/form-factor variants within the same IMAQ 1409 family.

Which video formats are supported by the PXI-1409?

NI lists RS-170/NTSC, CCIR/PAL, VGA 640 × 480 at 60 Hz, and programmable variable scan.

Does the PXI-1409 use the IMAQ-A6822 as the main hardware?

No. NI identifies the PXI-1409 as the primary image acquisition module, while the IMAQ-A6822 is an optional accessory connector block and cable.

Ask SOHO AssistantProduct & compatibility help