National Instruments USB-6525 product image 1 additional viewNational Instruments USB-6525 product image 1 additional viewNational Instruments USB-6525 product image 1 additional viewNational Instruments USB-6525 product image 1 additional viewNational Instruments USB-6525 product image 1 additional view
13 images: additional views below.Click to enlarge
National Instruments · Computer-based USB data acquisition

USB-6525

The NI USB-6525 is a bus-powered USB digital I/O device with eight isolated inputs and eight solid-state relay outputs. It supports industrial digital sensor monitoring and actuator switching within its specified electrical limits.

ManufacturerNational Instruments
ModelUSB-6525
Part Number779640-01
Product TypeIsolated digital I/O device with solid-state relay outputs
● Available to Order
Condition: confirmed per unit

Request current pricing and lead time for this model. Our team will confirm the exact equipment configuration and condition.

Fast RFQ

Quote: USB-6525

We will reply by email.
Free Shippingfull policy linked
30-Day Warrantystandard coverage
30-Day Returnspolicy applies
Technical Supportmodel & compatibility help
Digital inputs8 channel-to-channel isolated inputs
Digital outputs8 isolated solid-state relays
Input range-60 to +60 VDC
Relay switching limits60 VDC or 30 Vrms; 500 mA maximum per channel
ConnectionUSB 2.0; screw-terminal signal connections
SOHO Assistant
Ask about this exact model, a replacement, accessory, driver, rental or repair question.
Ask about specifications, compatibility, availability, rental or repair.
Ask SOHO Assistant
Overview

Product overview

Key product information and technical features.

The USB-6525 combines isolated digital sensing and relay switching in a computer-connected device. Its bus-powered design supports industrial sensor and actuator interfaces without a modular DAQ chassis.

Signal wiring connects directly to screw terminals. The outputs switch an external load circuit rather than supply a programmable output voltage; load power and wiring must follow the NI connection instructions.

  • Separate banks of eight isolated digital inputs and eight isolated relay outputs.
  • Programmable input filtering and change detection.
  • Configurable power-up output states and a watchdog timer.
  • P1.7/PFI 0 can serve as the input to a 32-bit event counter.
Verified specifications

Technical data

Verified product specifications.

Digital input channels8, channel-to-channel isolated
Digital input voltage range-60 to +60 VDC
Output channels and relay type8, channel-to-channel isolated, normally open SSR
Maximum relay switching voltage60 VDC / 30 Vrms
Maximum switching current per channel500 mA
Relay switching rate at 90% duty cycle5 operations/s
Event counter1 shared with P1.7/PFI 0; 32-bit; 5 kHz maximum input frequency
Bus interfaceUSB 2.0 full-speed, 12 Mb/s
Signal connectorsTwo 16-position screw-terminal plug headers
Operating temperature0 to 55 °C
Condition & included items

What the actual unit includes

Confirm condition, included accessories and revision before ordering.

Condition

Confirmed per unit.

Included

Device / accessories confirmed in quote.

Revision

Exact revision confirmed when relevant.

Compatibility

Complete the measurement chain

Review system components and compatibility requirements.

National Instruments

Manufacturer

USB 2.0

Computer interface

USB-6525

Isolated digital sensing and relay switching

Field connections

Direct screw-terminal wiring; no separate signal-interface accessory required.

Use external load power within relay ratings and follow NI guidance for inductive-load protection.
Manuals & software

Technical resources

Manuals, software and technical resources for this model.

Shipping, warranty & returns

Commercial terms

Review shipping, warranty and return terms before ordering.

Shipping
Free Shipping. Full policy terms apply.
Warranty
30-Day Warranty. Standard coverage applies.
Returns
30-Day Returns. Return policy applies.
Price / Availability
Contact SOHO ProLab for current quote and availability.
Lifecycle services

Source, rent or repair the exact model

Choose pricing, rental or repair for this exact model.

Explore equipment

Data Acquisition and Control Systems

Shipping, warranty and returns

FAQ

Product-specific questions

Product-specific answers based on available technical information.

Does the USB-6525 supply 60 V to a load?

No. The 60 VDC rating is a relay switching limit, not a generated voltage. The load circuit uses an external power source.

Does it require a separate terminal-block accessory?

Signals connect directly to the device's screw-terminal connections; a separate signal-interface accessory is not required.

Can it count external events?

Yes. P1.7/PFI 0 can be configured for a 32-bit rising-edge event counter, with a maximum input frequency of 5 kHz.