National Instruments NI 9949 RJ-50 to screw-terminal adapter terminal block
1 image: Click to enlarge
National Instruments · C Series strain/bridge input accessories

NI 9949

The NI 9949 is an RJ-50 to screw-terminal adapter for custom wiring to C Series strain/bridge input modules. It is a connectivity accessory, not a PXI Express acquisition module.

ManufacturerNational Instruments
ModelNI 9949
Part Number196809-01
Product TypeRJ-50 to screw-terminal adapter terminal block
● Available to Order
Condition: confirmed per unit

Request current pricing and lead time for this model. Our team will confirm the exact equipment configuration and condition.

Fast RFQ

Quote: NI 9949

We will reply by email.
Free Shippingfull policy linked
30-Day Warrantystandard coverage
30-Day Returnspolicy applies
Technical Supportmodel & compatibility help
FunctionRJ-50 signal breakout to screw terminals
Device connection10-pin female RJ-50
Supported device examplesNI 9237 with RJ-50; SCXI-1314T
Operating temperature-40 to 70 °C
SOHO Assistant
Ask about this exact model, a replacement, accessory, driver, rental or repair question.
Ask about specifications, compatibility, availability, rental or repair.
Ask SOHO Assistant
Overview

Product overview

Key product information and technical features.

The NI 9949 provides accessible screw-terminal connections for custom sensor wiring and integration with C Series strain/bridge input hardware.

NI identifies part number 196809-01 as a four-adapter kit. That manufacturer packaging description does not establish the contents of this individual catalog offering.

  • Female RJ-50 connection and female screw-terminal connection.
  • Numbered terminals provide one-to-one breakout of RJ-50 pins 1 through 10.
  • S terminals provide access to the connector shield.
Verified specifications

Technical data

Verified product specifications.

Manufacturer part number196809-01
Back-end connection10-pin female RJ-50
Front-end connection10-pin female screw terminal
Outer dimensions65.6 × 21.3 × 31.5 mm
Weight43 g
Operating temperature-40 to 70 °C
Condition & included items

What the actual unit includes

Confirm condition, included accessories and revision before ordering.

Condition

Confirmed per unit.

Included

Device / accessories confirmed in quote.

Revision

Exact revision confirmed when relevant.

Compatibility

Complete the measurement chain

Review system components and compatibility requirements.

National Instruments

Manufacturer

C Series strain/bridge input modules

Measurement hardware served by the accessory

NI 9949

RJ-50 screw-terminal wiring interface

CompactDAQ context

NI documents the NI 9949 in CompactDAQ strain and load bundles using RJ-50-connected NI 9237 modules.

Use an RJ-50 cable; NI warns that RJ-45 cables can damage pins 1 and 10.
Manuals & software

Technical resources

Manuals, software and technical resources for this model.

Shipping, warranty & returns

Commercial terms

Review shipping, warranty and return terms before ordering.

Shipping
Free Shipping. Full policy terms apply.
Warranty
30-Day Warranty. Standard coverage applies.
Returns
30-Day Returns. Return policy applies.
Price / Availability
Contact SOHO ProLab for current quote and availability.
Lifecycle services

Source, rent or repair the exact model

Choose pricing, rental or repair for this exact model.

Explore equipment

CompactDAQ

Shipping, warranty and returns

FAQ

Product-specific questions

Product-specific answers based on available technical information.

Is the NI 9949 a data acquisition module?

No. NI identifies it as an RJ-50 to screw-terminal adapter for C Series strain/bridge input modules.

Does it provide quarter-bridge completion by itself?

NI's NI 9237 quarter-bridge wiring example using the NI 9949 requires an external precision resistor to complete the bridge circuit.

What cable should connect the accessory to the measurement device?

Use RJ-50, not RJ-45. Consult the device manual for signal assignments.

Ask SOHO AssistantProduct & compatibility help