National Instruments SWB-2816A product image 1
National Instruments SWB-2816A product image 1 additional viewNational Instruments SWB-2816A product image 1 additional viewNational Instruments SWB-2816A product image 1 additional viewNational Instruments SWB-2816A product image 1 additional viewNational Instruments SWB-2816A product image 1 additional view
6 images: additional views below.Click to enlarge
National Instruments · NI SwitchBlock

NI SWB-2816A

NI SWB-2816A is the A-variant of NI’s SWB-2816 SwitchBlock matrix module family, providing an 8x46 reed relay matrix with row access for NI SwitchBlock systems.

ManufacturerNational Instruments
ModelSWB-2816A
Product TypeSwitchBlock matrix relay card
● Available to Order
Condition: confirmed per unit

Request current pricing and lead time for this model. Our team will confirm the exact equipment configuration and condition.

Fast RFQ

Quote: SWB-2816A

We will reply by email.
Free Shippingfull policy linked
30-Day Warrantystandard coverage
30-Day Returnspolicy applies
Technical Supportmodel & compatibility help
Topology1-wire 8 × 46 matrix
Rows8
Columns46
Crosspoints368
Maximum switching current0.25 A per channel
Maximum carry current0.3 A per channel
SOHO Assistant
Ask about this exact model, a replacement, accessory, driver, rental or repair question.
Ask about specifications, compatibility, availability, rental or repair.
Ask SOHO Assistant
Overview

Product overview

Key product information and technical features.

NI SWB-2816A is an NI SwitchBlock matrix relay card in the SWB-2816 family. NI identifies the family as an 8x46, 0.3 A reed matrix module for SwitchBlock, while the official product page distinguishes the A and B variants and lists NI 2816A as the version with row access. This makes the A designation important when selecting a module for systems that need direct access to rows as well as columns.

The NI 2816A/B specifications describe a 1-wire 8 × 46 matrix with 368 crosspoints and reed, non-latching relays. Official NI specifications list a maximum switching current of 0.25 A per channel, maximum carry current of 0.3 A per channel, maximum switching power of 3 W per channel and per crosspoint, and maximum switching voltage of 100 VDC or 70 VAC row-to-column. The module also provides eight analog bus lines labeled AB.

For signal performance, NI specifies DC path resistance of initially less than 1 Ω, end-of-life resistance of 2 Ω or greater, and open-channel isolation above 1×10^9 Ω. Typical thermal EMF is less than 50 µV, and typical bandwidth is at least 8 MHz at -3 dB with 50 Ω termination measured column-row-column. Physical details include a 96-position plastic SCSI connector, dimensions of 11.2 cm × 1.2 cm × 17.1 cm, and weight of 320 g.

  • 8x46, 0.3 A reed matrix module for NI SwitchBlock.
  • Variant A provides row access; NI product page lists Row Access = Yes for NI 2816A.
  • 1-wire 8 × 46 matrix topology.
  • Reed, non-latching relay type.
  • 368 crosspoints.
Verified specifications

Technical data

Verified product specifications.

Topology1-wire 8 × 46 matrix
Rows8
Columns46
Crosspoints368
Maximum switching current0.25 A per channel
Maximum carry current0.3 A per channel
Maximum switching voltage100 VDC / 70 VAC row-to-column; 100 V, CAT I row/column-to-ground
Maximum switching power3 W per channel; 3 W per crosspoint
DC path resistanceinitial 1×10^9 Ω
Bandwidth (typical, -3 dB, 50 Ω termination, column-row-column)≥8 MHz
Analog bus linesAB 8 lines
I/O connector96-position plastic SCSI
Dimensions11.2 cm × 1.2 cm × 17.1 cm
Weight320 g
Condition & included items

What the actual unit includes

Confirm condition, included accessories and revision before ordering.

Condition

Confirmed per unit.

Included

Device / accessories confirmed in quote.

Revision

Exact revision confirmed when relevant.

Compatibility

Complete the measurement chain

Review system components and compatibility requirements.

National Instruments

Manufacturer

NI SwitchBlock

Platform

SWB-2816A

SwitchBlock matrix relay card

Interface

96-position plastic SCSI

Manuals & software

Technical resources

Manuals, software and technical resources for this model.

Shipping, warranty & returns

Commercial terms

Review shipping, warranty and return terms before ordering.

Shipping
Free Shipping. Full policy terms apply.
Warranty
30-Day Warranty. Standard coverage applies.
Returns
30-Day Returns. Return policy applies.
Price / Availability
Contact SOHO ProLab for current quote and availability.
Lifecycle services

Source, rent or repair the exact model

Choose pricing, rental or repair for this exact model.

Explore equipment

Test Equipment Parts & Accessories

Shipping, warranty and returns

FAQ

Product-specific questions

Product-specific answers based on available technical information.

What is the difference between SWB-2816 and NI 2816A?

NI uses SWB-2816 as the SwitchBlock family/module name, while NI 2816A identifies the A variant of that module. NI documentation states SwitchBlock modules may appear in software as NI 2816A or NI 2816B, and the NI product page maps NI 2816A to the SWB-2816 family as the row-access version.

Can the NI SWB-2816A be used as a stand-alone module?

No. NI states that SwitchBlock modules require a PXI Carrier Module for SwitchBlock and cannot be used without the PXI Carrier Module.

Does the NI SWB-2816A provide row access?

Yes. NI’s product page explicitly lists Row Access as Yes for the NI 2816A variant, while NI overview documentation also distinguishes Type A from Type B pinout behavior.

Ask SOHO AssistantProduct & compatibility help