NI SCC-AI06 Isolated analog input module - equipment photo 1
NI SCC-AI06 Isolated analog input module - equipment photo 1 additional viewNI SCC-AI06 Isolated analog input module - equipment photo 1 additional view
3 images: additional views below.Click to enlarge
National Instruments · SCC signal conditioning

NI SCC-AI06

NI SCC-AI06 is an SCC-AI Series isolated analog input module designed for SCC signal-conditioning systems, providing 2 NRSE input channels with a ±100 mV nominal input range and ±10 V output.

ManufacturerNational Instruments
ModelSCC-AI06
Product TypeIsolated analog input module
● Available to Order
Condition: confirmed per unit

Request current pricing and lead time for this model. Our team will confirm the exact equipment configuration and condition.

Fast RFQ

Quote: SCC-AI06

We will reply by email.
Free Shippingfull policy linked
30-Day Warrantystandard coverage
30-Day Returnspolicy applies
Technical Supportmodel & compatibility help
Number of input channels2 NRSE
Nominal input range±100 mV
Output range±10 V
Gain100
Bandwidth10 kHz
Calibration input value for gain adjustment80 mV
SOHO Assistant
Ask about this exact model, a replacement, accessory, driver, rental or repair question.
Ask about specifications, compatibility, availability, rental or repair.
Ask SOHO Assistant
Overview

Product overview

Key product information and technical features.

NI SCC-AI06 is a primary SCC-AI Series isolated analog input module from National Instruments. NI identifies the SCC-AI family as isolated analog input modules and specifies the SCC-AI06 as the 2-channel NRSE variant with a nominal ±100 mV input range, ±10 V output range, gain of 100, and 10 kHz bandwidth. This places the module in the low-level voltage signal-conditioning range within the SCC-AI family rather than as an accessory or generic carrier component. https://download.ni.com/support/manuals/371066d.pdf

Within the module, NI specifies bank isolation at the module level rather than isolation between the two input channels. The SCC-AI06 therefore provides isolation per module, while its two channels are not isolated from each other. For the SCC-AI family specifications that apply to SCC-AI06, NI lists 100 MΩ input impedance for models in the applicable group, 4.5% maximum gain error trimmable to zero, 40 mV maximum offset error referred to input, and 100 dB typical CMRR at 60 Hz. https://download.ni.com/support/manuals/371066d.pdf

Installation and system integration follow the SCC hardware ecosystem. NI states that SCC-AI modules can plug into SCC-68 or SC-2345/2350 systems. Physical connections are through one 20-pin right-angle male connector and one removable 4-pin screw terminal. NI also lists channel-to-earth isolation ratings of 60 VDC continuous and 2300 Vrms withstand for 5 seconds, with maximum working input voltage to earth of 42.4 Vpeak or 60 VDC in Measurement Category I. https://download.ni.com/support/manuals/371066d.pdf

  • 2 NRSE input channels.
  • Nominal input range of ±100 mV.
  • Output range of ±10 V.
  • Gain of 100.
  • 10 kHz bandwidth.
  • Bank isolation per module; no isolation between the two channels.
Verified specifications

Technical data

Verified product specifications.

Number of input channels2 NRSE
Nominal input range±100 mV
Output range±10 V
Gain100
Bandwidth10 kHz
Calibration input value for gain adjustment80 mV
Input impedance100 MΩ
Gain error4.5% max (trimmable to zero)
Offset error40 mV max (RTI)
CMRR100 dB typical at 60 Hz
Isolation voltage, channel-to-earth60 VDC continuous
Isolation withstand2300 Vrms for 5 s
Maximum working voltage, channel-to-earth42.4 Vpeak or 60 VDC
Connector 120-pin right-angle male connector
Connector 2Removable 4-pin screw terminal
Dimensions1.87 × 7.93 × 3.55 cm
Weight37 g
NI part number777459-25
Condition & included items

What the actual unit includes

Confirm condition, included accessories and revision before ordering.

Condition

Confirmed per unit.

Included

Device / accessories confirmed in quote.

Revision

Exact revision confirmed when relevant.

Compatibility

Complete the measurement chain

Review system components and compatibility requirements.

National Instruments

Manufacturer

SCC signal conditioning

Platform

SCC-AI06

Isolated analog input module

Interface

20-pin right-angle male connector; removable 4-pin screw terminal

Manuals & software

Technical resources

Manuals, software and technical resources for this model.

Shipping, warranty & returns

Commercial terms

Review shipping, warranty and return terms before ordering.

Shipping
Free Shipping. Full policy terms apply.
Warranty
30-Day Warranty. Standard coverage applies.
Returns
30-Day Returns. Return policy applies.
Price / Availability
Contact SOHO ProLab for current quote and availability.
Lifecycle services

Source, rent or repair the exact model

Choose pricing, rental or repair for this exact model.

Explore equipment

Data Acquisition and Control Systems

Shipping, warranty and returns

FAQ

Product-specific questions

Product-specific answers based on available technical information.

What is the input range of the NI SCC-AI06?

NI specifies the SCC-AI06 nominal input range as ±100 mV.

How many channels does the NI SCC-AI06 provide?

NI lists the SCC-AI06 as having 2 NRSE input channels.

Does the NI SCC-AI06 isolate each channel independently?

No. NI states the SCC-AI modules provide bank isolation per module, but there is no isolation between the two channels on the module.

Which SCC systems accept the NI SCC-AI06?

NI states that SCC-AI modules can plug into SCC-68 or SC-2345/2350 systems.

What is the official NI part number for SCC-AI06?

NI lists SCC-AI06 with part number 777459-25 in the SCC System Configuration Worksheet.

Ask SOHO AssistantProduct & compatibility help