NI PXI-5690 is an NI PXI RF preamplifier, not a data acquisition module. NI documentation identifies it as a 3 GHz RF preamplifier, and the NI driver readme separately lists the PXI-5690 preamplifier from the PXI-5691 amplifier and PXI-5695 attenuator. This distinction is important when matching the module to RF signal-conditioning applications and software support. https://www.ni.com/docs/en-US/bundle/pxi-5690-getting-started/page/support.html https://www.ni.com/pdf/manuals/375126d.html
The standalone PXI-5690 specifications define a frequency range of 100 kHz to 3.0 GHz across 2 channels. Channel 0 is a fixed-gain path, while Channel 1 is a programmable-gain path. NI states that published specifications are valid after a 15-minute warm-up at 25 °C ambient with the calibration cycle maintained, and the recommended calibration interval is 1 year. https://www.ni.com/docs/en-US/bundle/pxi-5690-specs/page/specs.html
RF connectivity is provided through four SMA female 50 ohm ports: CH 0 IN, CH 0 OUT, CH 1 IN, and CH 1 OUT. NI specifies AC coupling on CH 0 IN and the CH 1 main input path. For performance, Channel 0 has gain calibration accuracy of ±0.4 dB, maximum output power of +20 dBm, typical output 1 dB compression of +18 dBm, and survival input power of -10 dBm maximum. Channel 1 main path also has ±0.4 dB gain calibration accuracy, +20 dBm maximum output power, typical output 1 dB compression of +16 dBm, and +20 dBm maximum survival input power with attenuation. https://www.ni.com/docs/en-US/bundle/pxi-5690-specs/page/specs.html